Line 2: Line 2:
  
  
-====== DM41X Snippets ======+====== DM41X Hints & Tips ======
  
 ===== Module Switching ===== ===== Module Switching =====
  
-Using the [[dm41x_ladybug_module| Ladybug module]] for Integer/Base calculations means it's impossible to also have the [[41z_module| 41Z complex number module]] and its library "plugged in" at the same time.+Using the [[dm41x_ladybug_module| Ladybug module]] for Integer/Base calculations means it's impossible to also have the [[41z_module| 41Z complex number module]] or the [[hp16c_emulator| HP16C simulator module]] and the necessary library "plugged in" at the same time. There is a clash between ''Library 4'' needed for ''41z'' (and also needed for ''16C'') and ''OS/4'' which is needed for ''Ladybug''.
  
 I've used the DM41X "module save/load" function to have different module-plugged states: I've used the DM41X "module save/load" function to have different module-plugged states:
  
-  * 41z.m41 : with 41Z deluxe and Library 4 modules plugged in and active +  * ''41z.m41'' : with ''41Z 2x2 Deluxe'' and ''Library 4'' modules active 
-  * lady.m41 : with boost, OS/4 and Ladybug modules plugged in and active+  * ''16c.m41'' : with ''HP16 C Simulator'' and ''Library 4'' modules active 
 +  * ''lady.m41'' : with ''Boost''''OS/4'' and ''Ladybug'' modules active 
 +  * ''adv.m41'' : with ''Advantage Pac'' module active 
  
 These are accessed via ''setup'' -> ''2. Module'' -> ''4. Load Modules'' -> ''1. Load AM list'' These are accessed via ''setup'' -> ''2. Module'' -> ''4. Load Modules'' -> ''1. Load AM list''
- + 
 +Choosing the required *.m41 file will automatically unplug/plug whichever modules were active when the config. was saved. 
 + 
 +This makes it easier to remember which supporting library/module are needed to use each particular module's functions. 
 + 
 +It's possible to also save the ''flash'' state - which modules have been pre-loaded into the DM41X's Flash Memory making them //available// to be //plugged in// using different options at the ''setup'' ''2. Module'' choices.... you'll work it out. 
 + 
 ===== Advantage Pac : Flag 21 ===== ===== Advantage Pac : Flag 21 =====
  